DammamZamil Plastics
The lap grid and valley lines sealed with EPDM at Zamil Plastics, with every section flood-tested.
View projectLeaking roof? An engineer calls you within 24 hours. Book a free roof survey
Where one roof sheet ends and the next begins further down the slope, the two overlap to form an end lap: a horizontal joint that crosses every rib of the roof. All the rainwater from the sheets above has to pass over it. ETCE's end lap waterproofing covers each of these joints with a 1.2 mm EPDM strip bonded across its full width, so water flows over the top instead of creeping into the overlap.
Zamil Plastics – DammamAn end lap faces the flow of water head-on. On long warehouse roofs, and especially low-pitch ones, water slows as it reaches the joint and can be drawn into the overlap by capillary action. Dust and sand blown in by Shamal winds settle along the step of the lap, hold moisture against the metal and hide the first signs of corrosion. In the Eastern Province, humid salty air speeds up rusting at the cut edge of the lower sheet, which sits damp inside the joint.
Sealant beads alone struggle here because the joint moves every day as the sheets expand in the sun and contract at night. EPDM is a flexible rubber membrane that stretches with that movement instead of cracking, and it shades the metal beneath from UV. Once bonded across the whole lap it forms a continuous waterproof skin over the joint that typically lasts beyond 20 years.
Site photos from ETCE projects in Saudi Arabia and Bahrain. Tap to enlarge.
It is the horizontal joint where an upper roof sheet overlaps the top of the sheet below, running across the slope. Long roofs use several sheets in each run, so a building can have several lines of end laps between ridge and gutter.
A bead of sealant sits on a narrow line where all the sheet movement is concentrated, so in Saudi heat it tends to split or peel within a few seasons. An EPDM strip spreads that movement over a wide, flexible band bonded to both sheets.
Yes. The membrane is soft enough to be worked into each rib and valley. That matters, because any void left under the strip would only move the leak rather than stop it.
They can, and on many roofs they are the main source of leaks. Our survey still checks the side laps and fasteners nearby, because a leak blamed on an end lap sometimes starts at a screw just above it.
Ask for a free survey of your roof's end laps. We will photograph every horizontal joint and quote the treatment line by line.
Leaking roof? An engineer calls you within 24 hours.
DammamThe lap grid and valley lines sealed with EPDM at Zamil Plastics, with every section flood-tested.
View project
DammamValley gutters, ventilators and HVAC-platform junctions waterproofed across ATCO's East & West factories.
View project
RiyadhTurbine ventilators, skylights and sheet laps sealed with EPDM on an industrial roof in Riyadh.
View project