RiyadhAlfa Laval
Turbine ventilators, skylights and sheet laps sealed with EPDM on an industrial roof in Riyadh.
View projectLeaking roof? An engineer calls you within 24 hours. Book a free roof survey
Glass roofs, glazed skylights and atriums on commercial buildings from Jeddah to Al Khobar look impressive until the joints between the panes start letting water in. ETCE waterproofs these joints with a strip of EPDM bonded over the line of each joint, a detail that keeps holding through Saudi summers when the glass itself becomes extremely hot.
Alfa Laval – RiyadhMost glazed roofs rely on a single bead of sealant between the pane and its frame, or between neighbouring panes. Glass in direct sun gets far hotter than the air around it, and every day it expands and contracts against its frame. Over time the sealant loses its grip, hardens or develops fine cracks along its edge. Running a fresh bead over the old one rarely lasts, because the new material is bonding to a surface that has already failed.
Instead of relying on that narrow bead, ETCE covers the whole joint. A strip of EPDM 100–150 mm wide is centred over each joint and bonded to the glass and frame on both sides with Promax Bonding Adhesive. The adhesive is rated for surface temperatures up to 120 °C, so it stays put and does not peel even at the height of summer, while the flexible membrane follows the daily movement of the panes.
Site photos from ETCE projects in Saudi Arabia and Bahrain. Tap to enlarge.
Each strip covers only a narrow band along the joint line, so the rest of every pane stays clear. The roof continues to let daylight in much as it did before.
A new bead of sealant sits on top of old, failed material and faces the same heat and movement that broke it. A bonded EPDM strip spans the whole joint and grips the glass on both sides, so it does not depend on that narrow bead.
No. The strips are applied over the existing joints from the outside, so the glazing stays in place and the building remains open throughout the work.
The same approach suits glazed skylights on factories and warehouses, and other roof joints that were originally closed with sealant alone. During the free survey our engineer will confirm which joints are suitable.
Book a free survey of your glass roof or skylights and receive a joint-by-joint photo report with an itemised quotation. Call +966 54 352 0904.
Leaking roof? An engineer calls you within 24 hours.
RiyadhTurbine ventilators, skylights and sheet laps sealed with EPDM on an industrial roof in Riyadh.
View project
Al KhobarWall-cladding flashings, skylights, laps and fasteners sealed with EPDM in Al Khobar.
View project
DammamCowl vents, exhaust hoods, skylights and the ridge sealed with EPDM on a radiator factory.
View project