B&R Gulf: Metal Roof & Gutter Waterproofing in Dammam

Parapet gutters, the ridge line, laps and fasteners sealed across a long-span roof, then water-tested.

Dammam, Saudi ArabiaIndustrialEPDM system
Get a free survey for your roof
B&R Gulf metal roof & gutter waterproofing in Dammam - ETCE EPDM work, photo 1 of 3 B&R Gulf – Dammam

Project photos

Tap any photo to enlarge. All photos were taken on site by the ETCE team.

The challenge

B&R Gulf's building has a long-span roof that drains into parapet gutters along the walls. Where the roof sheets meet the parapet, water sits against the joint after every rain, and the fastener rows and end laps across the slopes had started to let water through.

What ETCE did

ETCE lined the parapet gutters with EPDM taken up the wall face and down under the roof sheets, sealed the ridge line with twin EPDM runs, closed the end laps and sealed the fastener heads across the roof. Turbine ventilator bases were flashed, and the gutters were water-tested with hoses to confirm the lining held.

Failure points treated on this roof

Materials & method

  • EPDM membrane (1.2 mm) cut to width for each detail: UV-stable and flexible at Gulf roof temperatures.
  • Promax Bonding Adhesive, rated for surface temperatures up to 120°C, for a permanent bond to the metal sheets.
  • Preparation first: old coatings, failed sealant and loose rust removed so the membrane bonds to sound metal.
  • Roof-side, zone-by-zone execution so the building below keeps operating with no shutdown.
  • Working-at-height HSE: trained crews, full PPE and safety lifelines on every roof.

The result

From gutter to ridge, the roof's water paths are now sealed with one continuous membrane system, photographed and tested at handover.

Seeing leaks like this at your industrial building in Dammam?

Send us a few details and an ETCE engineer will call you within 24 hours to arrange a free roof survey. You get a written report with photos of every failure point and an itemised quotation, with no obligation.

Project facts

  • ClientB&R Gulf
  • LocationDammam, Saudi Arabia
  • SectorIndustrial
  • RoofLong-span metal roof with parapet gutters and turbine ventilators
  • Failure points treated
    GuttersWall junctionsRidge lineEnd lapsScrew headsVentilatorsFlood-tested
  • SystemEPDM membrane + Promax Bonding Adhesive
  • WarrantyUp to 15 years on ETCE EPDM systems

Free roof survey

Leaking roof? An engineer calls you within 24 hours.

Your details are only used to contact you about your roof.

More projects like this

Zamil Plastics factory roof waterproofing in Dammam - ETCE EPDM work, photo 1 of 3Dammam
Plastics manufacturing

Zamil Plastics

The lap grid and valley lines sealed with EPDM at Zamil Plastics, with every section flood-tested.

Side lapsEnd lapsGuttersFlood-tested
View project